Blueprints
Found in 97 Collections and/or Records:
7175-75 -- Details: Station 8+35.50 to Sand Dam Landing and Station 39+41.13 to Bridge Landing Stairways, 1977-09-20
Drawn by: K.P.
Scale: Various
Drawing contains details of stairway channel with hand rail, stairway tred and mounting bracket, detail for mounting stairway to landing bracket, stairway to landing bracket, and bottom landing plate. Also featured on the drawing is a bill of materials.
D-5-091 -- Acid Tank Storage Commercial Muuriatic Plans Specifications. , 1925-07-11
Drawn by: G.W.M.
Drawing features a partical section and partial plant for an acid tank. There is a series of notes titled "Specications for construction and assembling redwood or fir tanks for the storage of muriatic acid.
D-9-002 -- Auto Repair Shop & Garage Window Details, 1941-08-19
Drawn by: R.S.F.
Drawing shows a typical section of a window header and window sill for the Auto Repair Shop and Garage.
D-9-003 -- Acid Bottle, 1941-11-29
Drawn by: H.J.S.
Scale 1/2 Size
Drawing shows the side view of an acid bottle.
D-9-004 -- Disc for Flue Cleaner Bender Park Plant, 1946-02-12
Drawn by: Warren
Traced by: Warren
Scale: As shown.
Drawing of a plan (scale: full size) and enlarged detail (scale: 3" = 1") for a disc for the flue cleaner at the Bender Park Plant, charge number 6112.
D-9-005 -- Electrical Depeartment Motor Wash Room, 1946-04-02
Drawn by: L.G.W.
Traced by: L.G.W.
Scale: 1" = 1"-0"
Drawing show a 12 inch diameter vent stack and a 6 in diameter vent stack for the Electral Department's Motor Wash Room, order number, 5112.
D-9-006 -- Brick Lintel for Electrical. Dept. Motor Wash Room, 1946-04-02
Drawn by: H.J.S.
Scale: 1-1/2" = 1'-0"
Drawing shows teh brick lintel for the Electrical Department's Motor Wash Room.
D-9-007 -- Outdoor Fireplace, 1946-06-13
Drawn by: H.J.S.
Traced by: H.J.S.
Scale: 1/2" = 1'-0"
Drawing of the front, side, and top view of an outdoor fireplace.
D-11-003 -- Open Cut 33KV Power Line Detail of Crossarms, 1982-07-09
Drawn by: S.L.R.
Scale: 1" = 1'
Drawing features the details of the cross arms for a 33KV Power Line for the Open Cut.
D-11-004 -- Dam at 1700' Star Pillar Crosscut, 1984-04-12
Drawn by: DM
SCale: 1/2" = 1'
Drawing features pipe detials and rails for the Dam at 1700 foot level in the Star Pillar Crosscut.